Development and Validation of RP-HPLC Method for Simultaneous Estimation of Gatifloxacin and Loteprednol Etabonate in Pharmaceutical Dosage Form
Ankit B. Patel*, Dipti B. Patel
Department of Quality Assurance, S.K. Patel College of Pharmaceutical Education & Research,
Ganpat University, Ganpat Vidyanagar – 384012, Mehsana, Gujarat, India.
*Corresponding Author E-mail: abpatel89@gmail.com
ABSTRACT:
A simple, accurate, and rapid reversed phase high performance liquid chromatographic method has been developed and validated for the simultaneous estimation of Gatifloxacin (GTF) and Loteprednol etabonate (LTP) in ophthalmic suspension. The separation was carried out using mobile phase consisting of methanol: phosphate buffer (pH, 6.0): Acetonitrile (65:25:10 v/v/v) with flow rate 1.0 ml/min using PDA detection at 264 nm. The column used was Phenomenex C18, (150 mm x 4.6 mm i.d., 5 µm). The method was linear over a concentration range 2 - 35 μg/ml for both drugs. The retention time of Gatifloxacin and Loteprednol etabonate were found to be 2.31 min and 5.36 min, respectively. Results of analysis were validated statistically. The mean recovery was 100.73 ± 1.11 and 99.74 ± 0.69 for GTF and LTP, respectively. The limit of detection (LOD) and the limit of quantification (LOQ) for GTF and LTP were found to be 0.103 and 0.312 µg/ml and 0.118 and 0.360 µg/ml, respectively. The results of the study showed that the proposed RP-HPLC method was found to be simple, sensitive, precise and accurate and also useful for the routine analysis of GTF and LTP in pharmaceutical dosage form.
KEYWORDS: Gatifloxacin, Loteprednol etabonate, RP-HPLC, Validation.
INTRODUCTION:
Gatifloxacin (GTF) is chemically 1-cyclopropyl-6-fluoro-8-methoxy-7-(3-methylpiperazin-1-yl)-4-oxo-quinoline-3-carboxylic acid (Figure 1) is a well known antibacterial drug1. Gatifloxacin is an antibiotic of the fourth-generation fluoroquinolone family. It is official in Indian Pharmacopoeia (IP). IP2 describe HPLC methods for its estimation. Literature survey reveals UV3,4,5,6, HPLC7,8,9,10,11, HPTLC12,13, Colorimetric14 and Spectroflurometric15 for determination of Gatifloxacin individually and other combinations in pharmaceutical and biological preparations. Loteprednol etabonate (LTP) is chemically chloromethyl 17-ethoxycarbonyloxy-11-hydroxy-10,13-dimethyl-3-oxo-7,8,9,11,12,14,15, 16-octahydro-6H-cyclopenta[a] phenanthrene-17-carboxylate16 (Figure 2). It is cortricosteroids. It is not official in any pharmacopoeia. Literature survey reveals HPLC17,18,19 for determination of LTP with degraded products, other combination in pharmaceutical and in biological preparation.
However, there is no work has been reported for the estimation GTF and LTP simultaneously. The present communication describes simple, sensitive, rapid, accurate, precise and cost effective RP-HPLC method for simultaneous estimation of both drugs in pharmaceutical dosage form.
|
Figure 1: Chemical structure of Gatifloxacin (GTF) |
Figure 2: Chemical structure of Loteprednol etabonate (LTP) |
MATERIALS AND METHODS:
Apparatus
RP-HPLC instrument (Shimadzu, LC-20AD, Japan) equipped with a photodiode array detector, phenomenex C18 column (150 x 4.6 mm, 5 µ particle size) was used. Chromatograms were automatically obtained by LC-Solution system software. A Sartorius CP224S analytical balance (Gottingen, Germany), an ultrasonic bath (Frontline FS 4, Mumbai, India), Whatman filter paper no. 41 (Millipore, USA) were used in the study.
Reagent and materials
GTF and LTP bulk powder was kindly gifted by Sun Pharmaceuticals Ltd., Vadodara, Gujarat, India. Methanol (HPLC Grade), ACN (HPLC Grade) and water (HPLC grade) were procured from Finar Chemicals Ltd., Ahmedabad, India. Sodium dihydrogen ortho phosphate and disodium hydrogen ortho phosphate (AR grade, Finar Chemicals Limited, Ahmedabad, India) were used in the study.
Preparation of phosphate buffer solution
Phosphate buffer (pH 6.0) was prepared by dissolving 1.56 g sodium dihydrogen ortho-phosphate dihydrate and 0.35 g disodium hydrogen phosphate dihydrate in 1000 ml HPLC-grade water and the pH adjusted to 6.0 by dilute ortho-phosphoric acid.
Preparation of standard stock solutions of GTF and LTP (100 μg/ml)
An accurately weighed standard powder of GTF and LTP (10 mg) were transferred to 100 ml separate volumetric flasks and dissolved in mobile phase with 5 min sonication. The flasks were shaken and volumes were made up to mark with mobile phase to give a solution containing 100 μg/ml of each GTF and LTP.
Preparation of sample solution
From the Ophthalmic formulation containing 0.3 % w/v GTF & 0.5 % w/v LTP, 1 ml taken in 50 ml volumetric flask and the volume was adjusted to mark with mobile phase. This solution (2.0 ml) was taken in to a 10 ml volumetric flask and the volume was adjusted up to mark with mobile phase to get a final concentration of GTF (12 µg/ml) and (20 µg/ml).
Chromatographic Condition
To optimize the RP-HPLC parameters, several mobile phase compositions were tried. A satisfactory separation and good peak symmetry for GTF and LTP was obtained with a mobile phase methanol: phosphate buffer (pH-6.0) : ACN (65:25:10 v/v/v) at a flow rate 1.0 ml/min. Quantification was carried out at 264 nm based on peak area. Analysis was performed at ambient temperature.
Method Validation
The proposed method was validated according to the International Conference on Harmonization (ICH) guidelines 20.
Calibration Curve (linearity)
Calibration curves were constructed by plotting peak area vs. concentration of GTF and LTP, and regression equation were calculated. The calibration curves were plotted over the concentration range of 2 - 35 μg/ml for both drugs. From standard stock solution of mixture of GTF and LTP (0.2, 0.5, 1.0, 1.5, 2.0, 2.5, 3.0 and 3.5 ml) were transferred to a series of 10 ml volumetric flask and diluted to the mark with mobile phase. Aliquots (20 µl) of each solution were injected under the operating chromatographic condition as described above.
Method precision (Repeatability)
The precision of the instrument was checked by repeated injection (n = 6) of standard solutions of GTF (10 µg/ml) and LTP (10 µg/ml) under the same chromatographic condition and measurement of peak area, retention time and tailing factor. The low %RSD values (less than 2%) indicates that proposed method is repeatable.
Intermediate precision (Reproducibility)
The intraday and interday precision of the proposed method was determined by analyzing the corresponding responses 3 times on the same day and on 3 different days over a period of 1 week for 3 different concentrations of standard solutions of GTF (15, 20, 25 µg/ml) and LTP (15, 20, 25 µg/ml). The result was reported in terms of relative standard deviation (% RSD).
Limit of detection and Limit of quantification
LOD and LOQ of drugs can be calculated using the following equations designated by International Conference on Harmonization (ICH) guidelines.
LOD = 3.3 × σ/S
LOQ = 10 × σ/S
Where, σ = the standard deviation of the response and S = slope of the calibration curve.
Accuracy (Recovery study)
The accuracy of the method was determined by calculating recovery of GTF and LTP by the standard addition method. Known amounts of standard solutions of GTF and LTP (50, 100, 150 %) were added to prequantified sample solutions of GTF and LTP. The amounts of GTF and LTP were estimated by applying obtained values to the respective regression equation of the calibration curve.
Estimation of GTF and LTP from Ophthalmic Formulation
Aliquot (20 µl) of sample solution was injected under the operating chromatographic condition as described above and peak area was determined for both drugs. From these area values, the concentrations of GTF and LTP were determined using respective calibration graph. The analysis procedure was repeated six times with ophthalmic formulation.
RESULTS AND DISCUSSION:
The aim of this study was to develop a HPLC method for the analysis of Gatifloxacin and Loteprednol etabonate in Pharmaceutical dosage forms. Overlain UV spectrum showed that both drugs showed good absorbance at 264 nm, hence the wavelength of 264 nm was selected for quantification of GTF and LTP (Figure 3). The best mobile phase selected for its determination was methanol: phosphate buffer (pH-6.0): acetonitrile in the ratio of 65: 25: 10 v/v/v. The mobile phase allowed the elution of GTF and LTP with good separation and retention time (tR) (figure 4). System suitability test parameters for GTF and LTP for the proposed method are reported in Table 1.
Figure 3: Overlain U.V. Spectrum of GTF and LTP.
Figure 4: Chromatogram of standard solution of GTF and LTP (100 μg/ml) at 264 nm
Table 1: System suitability parameters of chromatogram
|
System suitability parameter |
GTF ± RSD (n = 5) |
LTP ± RSD (n = 5) |
|
Retention time(min) |
2.31 ± 0.91 |
5.36 ± 0.42 |
|
Theoretical plate (N) |
2056.33 ± 1.48 |
5776 ± 0.66 |
|
Tailing factor (AS) |
1.64 ± 0.54 |
1.37 ± 0.82 |
|
Resolution (RS) |
9.37 ± 0.43 |
|
Excellent Linearity was obtained between Concentration and area of GTF and LTP in the concentration range of 2 – 35 µg/ml for both drugs. The results of calibration studies are summarized in Table 2.
The low RSD value of intraday (0.369 – 0.633 % for GTF and 0.382 – 0.799 % for LTP) and interday (0.475 – 1.032 % for GTF and 0.460 - 0.940 % for LTP) at 264 nm, reveal that proposed method is precise. The limit of detection (LOD) and limit of quantification (LOQ) for GTF and LTP were found to be 0.103 and 0.312 µg/ml and 0.118 and 0.360 µg/ml, respectively.
Table 2: Linearity Parameters (n=5)
|
Parameters |
GTF |
LTP |
|
Linearity range |
2 - 35 |
2 - 35 |
|
Regression equation y = mx + c |
y = 36348x + 33985 |
y = 29249x - 3319 |
|
Slope |
36348 |
29249 |
|
Intercept |
33985 |
- 3319 |
|
Correlation coefficient (r2) |
0.997 |
0.998 |
These data show that method is sensitive for the determination of GTF and LTP. The recovery experiment was performed by the standard addition method. The mean recoveries were 100.73 ± 1.11 and 99.74 ± 0.69 for GTF and LTP, respectively (Table 3). The results of recovery studies indicate that the proposed method is highly accurate.
Table 3: Recovery study
|
Drug |
Level |
Amount of sample taken (µg/ml) |
Amount of standard spiked (%) |
Mean % Recovery ± RSD |
|
GTF |
I |
6 |
50 % |
99.75 ± 0.67 |
|
II |
6 |
100 % |
100.78 ± 1.55 |
|
|
III |
6 |
150 % |
101.68 ± 1.12 |
|
|
LTP |
I |
10 |
50 % |
99.49 ± 0.83 |
|
II |
10 |
100 % |
100.64 ± 0.79 |
|
|
III |
10 |
150 % |
99.10 ± 0.47 |
Table 4: Analysis of ophthalmic formulation of GTF and LTP by proposed method
|
Sample No. |
Label Claim |
Amount Found |
% Label Claim |
|||
|
GTF (% w/v) |
LTP (% w/v) |
GTF (% w/v) |
LTP (% w/v) |
GTF (%) |
LTP (%) |
|
|
1 |
0.3 |
0.5 |
0.3414 |
0.5056 |
100.45 |
101.11 |
|
2 |
0.3 |
0.5 |
0.2989 |
0.4876 |
99.64 |
97.52 |
|
3 |
0.3 |
0.5 |
0.2984 |
0.5114 |
99.47 |
102.28 |
|
4 |
0.3 |
0.5 |
0.3038 |
0.4888 |
101.26 |
97.76 |
|
5 |
0.3 |
0.5 |
0.3049 |
0.4984 |
101.64 |
99.69 |
|
6 |
0.3 |
0.5 |
0.3061 |
0.4917 |
102.03 |
98.33 |
|
Mean |
100.75 |
99.45 |
||||
|
S.D. |
1.06 |
1.93 |
||||
Figure 5: Chromatogram of sample solution of GTF (12 µg/ml) and LTP (20 µg/ml) at 264 nm
The assay of formulation show a good agreement on label claims (Table 4). No interference of the excipients with the retention time of drugs appeared (figure 5); hence the proposed method is applicable for the routine simultaneous estimation of GTF and LTP.
CONCLUSION:
The proposed method showed acceptable linearity, sensitivity, precision and accuracy. The results of the analysis of ophthalmic formulation by the proposed method are highly reproducible and reliable. The method can be used for the routine analysis of the GTF and LTP in formulation without any interference of excipients.
ACKNOWLEDGMENTS:
The authors are grateful to Sun Pharmaceuticals Ltd. Vadodara, Gujarat, India for providing gift samples of Gatifloxacin and Loteprednol etabonate and also to Department of Quality Assurance, S.K. Patel College of Pharmaceutical Education and Research, Ganpat University, Mehsana, Gujarat, India for providing the facilities to carry the research work.
REFERENCES:
1. Maryadele. J. O’ Neil. The Merck Index: An Encyclopedia of chemicals, drugs and biologicals, 14th edition. New Jersey: Published by Merck Research Laboratories, Division of Merck and Co., Inc. Whitehouse station, 2006, p.4376.
2. Indian Pharmacopoeia. Vol. III. The Controller of Publication. 6th ed. Govt. of India. New Delhi. 2010, p.1402-1404.
3. K Ilango, P Valentina, K.S. Lakshmi, A. Canhea, S.R. Abraham, V.B. Raju, A.K. Kumar, UV Spectroscopic And Colorimetric Methods For The Estimation Of Gatifloxacin In Tablet Dosage Forms. Indian Journal of Pharmaceutical Sciences, 68(2), 2006, 273-275.
4. S. Lakshmi, A. Muthukumaran, Spectrophotometric Determination Of Gatifloxacin In Pharmaceutical Formulations And Biological Sample, Indian Journal of Pharmaceutical Sciences, 2006, 68(5), 672-675.
5. S. Paramane et al., Simultaneous Spectrophotometric Estimation of Gatifloxacin and Ornidazole In Tablet Dosage Form, Indian Journal of Pharmaceutical Sciences, 2006, 68(6), 819-821.
6. P. U Patel et al., Simultaneous Spectrophotometric Estimation of Gatifloxacin and Ornidazole In Mixture, Indian Journal of Pharmaceutical Sciences, 2005, 67(3), 356-357.
7. S. Lakshmi, A. Muthukumaran , RP-HPLC Estimation Of Gatifloxacin In Tablets, Indian Journal of Pharmaceutical Sciences, 2005, 67(3), 367-369.
8. T.R. Shirke, N. Pai, Reverse Phase High Performance Liquid Chromatographic Determination of Gatifloxacin in gatifloxacin Eye Drops, Asian Journal of Chemistry, 2004, 16 (1), 546-548.
9. K. R. Sireesha and K. Prakash, Simultaneous Determination Of Gatifloxacin And Dexamethasone Sodium Phosphate In Bulk And Pharmaceutical Formulations by HPLC African Journal of Pharmacy and Pharmacology, 2011, 5(17), 1990-1995.
10. S.N. Razzaq et al., Development And Validation Of Gatifloxacine And Ketorolac Tromethamine In Combined Dosage Form By Liquid Chromatographic Method, Journal of Liquid Chromatography and Related Technologies, 2012, 35(5), 651-661.
11. A. B. Patel , N. J. Shah, N. M. Patel, Development and Validation of HPLC Method for the Simultaneous Estimation of Satranidazole and Gatifloxacin in Tablet Dosage Form. International Journal of ChemTech Research, 2009, 1(3), 587-590.
12. S.A. Shah et al., A Simple And Sensitive HPTLC Method For Estimation Of Gatifloxacin In Tablet Dosage. Indian Journal of Pharmaceutical Sciences, 2004, 66 (3), 306-308.
13. G. Sowmiya et al., HPTLC Method For The Determination Of Gatifloxacin In Human Plasma, Indian Journal of Pharmaceutical Sciences, 2007, 69(2), 301-302.
14. J. Jane, E.V.S. Subrahmanyam, D. Sathyanarayana, Spectrophotometric Determination of Gatifloxacin, Asian Journal of Chemistry, 2006, 18 (4), 3210-3212.
15. K. Venugopal, S. Movva, R.N. Saha, New, Rapid, And Sensitive Spectrofluorimetric Method For The Estimation Of Gatifloxacin In Bulk And Formulation, Indian Journal of Pharmaceutical Sciences, 2006, 68(6), 726-730.
16. Maryadele. J. O’ Neil. The Merck Index: An Encyclopedia of chemicals, drugs and biologicals, 14th edition. New Jersey: Published by Merck Research Laboratories, Division of Merck and Co., Inc. Whitehouse station, 2006, p.967.
17. V.L. McDevitt , J. Huang , M.J. Brubaker, Stability Indicating Gradient HPLC Method For The Determination Of Loteprednol Etabonate And Related Substances In A Finished Ophthalmic Product, Bausch & Lomb Pharmaceuticals, Tampa, FL.
18. S. Yasueda et al., An HPLC Method To Evaluate Purity Of A Steroidal Drug, Loteprednol Etabonate, Journal of Pharmaceutical and Biomedical Analysis, 2004, 36, 309–316.
19. G. Lunn , HPLC Methods for recently approved Pharmaceuticals, A John Wiley & Sons INC. Publications, Hoboken, New Jersey, 2005, 362-363.
20. The International Conference on Harmonization, Q2 (R1), Validation of Analytical Procedure, Text and Methodology, 2005.
Received on 05.04.2013 Modified on 12.04.2013